Temperature sensor type SGN

Type SGN

For hygeniec use

  • Threaded thermometer/cable sensor for hygienic use in the food industry.
  • The measuring element is according to IEC 751.
  • The protective sheath is standard of stainless steel, AISI 316 TI.
  • The connection cable is standard of silicone, with inner shield. Protection at junction: IP 65.
  • Mounting thread is 3/8"BSP.
  • Response time (mean values) measured at velocities in:
    water at 0.4 m/s: t0.5 < 5 sec.
  • Recommended measuring current:  max. 2 mA.
  • Senmatic only guarantee, that the part in contiguity with food, comply with the demands of the Danish Veterinary and Food Administration.

 

Contact us for more information