Resistance sensors for high & low temperature range using Pt100/Pt500/Pt1000
- for a wide range of industrial applications.
- Pt100/Pt500/Pt1000 platinum- and Ni-elements of glass, ceramics or thin film
- DIN-standardized
- Marine approval (eg DNV-GL, BV, RINA) for selected sensors
- Wire sensors
- Head-mounted sensors
- Tank thermometers
- Multi-spot sensor
- Atex approved
Usage of the sensors
- Senmatic’s Resistance Temperature sensors can be used for a wide range of industrial processes, customized after DIN-standard.
- Pt100/Pt500/Pt1000 platinum- and Ni-elements of glass, ceramics or thin film are used in different industrial applications. Depending on application the Resistance sensor can be delivered with transmitter for output signal 4-20 mA.
Accurate measurement
- The design of the Resistance sensor gives an accurate measurement and minimized reaction time.
- Resistance temperature sensors are normally used for temperature measurement between -50°C / -91°F and 600°C / 1092°F depending on sheath material and choice of element.
Below you can find all resistance thermometers divided into groups

Type A - Straight thermometer - Form A
With removable insert - for the low pressure range

Type B - Threaded thermometer
With extension length and removable insert - low-pressure range

Type BF - Threaded thermometer
With fixed insert - optional extension length - for the low pressure range

Type DMH - Extension length/exhangeable insert
Used in diesel engines in exhaust and cooling water systems.

Type DW - Weld-in thermometer
For gases, water and vapours - for the high-pressure range

Type HMI60 - Measuring insert with form B-head
With Ø6 insertion tube - for use mainly in the low pressure range

Type HMI80 - Measuring insert with form B-head
With Ø8 insertion tube - for use mainly in the low pressure range

Type HMMI - Mineral-insulated measuring insert
For use up to 600°C - mainly in the low pressure range

Type MI60 - Measuring insert for form A-B-D
With Ø6 insertion tube - for form A-B-D and mounting in B-head

Type MI80 - Measuring insert for form A
With Ø8 insertion tube - for form B and mounting in B-head

Type MMI - Mineral-insulated measuring insert
Designed for form A-B-C-D-E-F-G and mounting in B-head

Type PTE - Wire sensor - straight thermometer
For mouting in immerrsion wells, in gases and Machinery e.g. bearings

Type PTR - Threaded thermometer - Classified
With fixed insert and without extension length

Type PTVP - For wall mounting in refrigerated areas
For measurement of temperatures in rooms, e.g. in refrigerated holds, cargo and freeze compartments.

Type B - Threaded thermometer
With extension length and removable insert - low-pressure range

Type BF - Threaded thermometer
Fixed insert - optional extension length - the low pressure range

Type BJ - Straight cable sensor with bayonet
For measurement of temperatures in machinery, tools, bearings etc.

Type BL - for ambient air measurement
Straight thermometer for use in e.g. air ducts - with exchangeable insert.

Type DMH - Extension length/exhangeable insert
Used in diesel engines in exhaust and cooling water systems.

Type GW - Wire sensor with fixed thread
For mounting directly in thermowells in gases, pipelines and containers.

Type MNS - Mineral-insulated tank thermometer
Used for measurement in insulation and concrete surroundings

Type NS - Tank thermometer - roll-up sensor
For tank systems, e.g. in oil tankers as part of volume measuring system

Type PMK - Mineral-insulated with cable
Fast response time, good resistance to vibrations / harsh environments

Type PTE - Wire sensor - straight thermometer
For mouting in immerrsion wells, in gases and Machinery e.g. bearings

Type PTL - for cargo compartments
For use in refrigerated cargo vessels, cold rooms, and in basins and tanks

Type PTR - Threaded thermometer - Classified
With fixed insert and without extension length

Type PTV - for mounting on walls
For Measurement of temperatures in rooms

Type S - with angular connector
Classified - for use in gases, vapours and fluids.

Type BJ - Straight cable sensor with bayonet
For measurement of temperatures in machinery, tools, bearings etc.

Type CLE - Wire sensor for clamp mounting
Used for Measurement of temperatures

Type GW - Wire sensor with fixed thread
For mounting directly in thermowells in gases, pipelines and containers.

Type PMK - Mineral-insulated with cable
Fast response time, good resistance to vibrations and harsh environments.

Type PTE - Wire sensor - straight thermometer
For mouting in immerrsion wells, in gases and Machinery e.g. bearings

Type PTI - insertion thermometer - Classified
For measurement of temperatures in e.g. meat and fruit

Type PTL - for cargo compartments
For use in refrigerated cargo vessels, cold rooms, and in basins and tanks

Type PV - Wire sensor with angular bending
For measurement of temperatures in machinery

Type SGN - Mini sensor
With reduced tip for fast response time

Type HTMS - multi-spot thermometer
For measurement in multiple spots in high temperature areas

Type MNS - Mineral-insulated tank thermometer
Used for measurement in insulation and concrete surroundings

Type NL Cryogenic - multi-spot sensor
For cryoginic use - measurement in multiple spots -170°C to +95°C

Type NLI - Multi-spot sensor - Measurement of volume
Used for measuring of average temperatures in tank systems

Type NS - Tank thermometer - Roll-up sensor
For measurement of temperatures in pipelines and tank systems

Type OPE - with Ex-head
For use in refineries, chemical plants and harzardous installations

Type OPX - with Ex-head / reduced tip
Flanged mounted thermometer - fast response time

Type WLS - Water-Level-Sensor - multi-spot sensor
For continuous measurement of the water / oil interface

Type DMH - With extension length and exhangeable insert
Used in gases, vapours, diesel engines in exhaust and cooling water systems.

Type HMMI - Mineral-insulated measuring insert with B-head
For use up to 600°C - mainly in the low pressure range

Type MMI - Mineral-insulated measuring insert
Designed for form A-B-C-D-E-F-G and also for mounting in B-head

Type MNS - Mineral-insulated tank thermometer
Used for measurement in insulation and concrete surroundings

Type PMK - Mineral-insulated with cable
Fast response time, good resistance to vibrations and harsh environments.

Type BN - with union nipple and fixed insert
For use in gases, vapours and fluids e.g. in sealed pipelines

Type CL - Clamp mounting and fixed insert
Measurement of temperatures

Type CLE - Clamp mounting and fixed insert
For Measurement of temperatures

Type HR - reduced tip for fast response time
For Measurement of temperatures

Type SGN - Mini sensor
Fast response

Type MCB - Marine Connection Box
Enclosure for sensors and transmitters

Type A - Straight thermometer - Form A
With removable insert - for the low pressure range

Type B - Threaded immersion thermometer
With extension length and removable insert - low-pressure range

Type BF - Threaded thermometer
With fixed insert - optional extension length - for the low pressure range

Type BJ - Straight cable sensor with bayonet
For measurement of temperatures in machinery, tools, bearings etc.

Type BL - for ambient air measurement
Straight thermometer for use in e.g. air ducts - with exchangeable insert.

Type BN - with union nipple and fixed insert
For use in gases, vapours and fluids e.g. in sealed pipelines

Type CL - Clamp mounting and fixed insert
Measurement of temperatures

Type CLE - Wire sensor for clamp mounting
Used for Measurement of temperatures

Type DMH - With extension length and exhangeable insert
Used in gases, vapours, diesel engines in exhaust and cooling water systems.

Type DW - Weld-in thermometer
For gases, water and vapours - for the high-pressure range

Type GW - Wire sensor with fixed thread
For mounting directly in thermowells in gases, pipelines and containers.

Type HMI60 - Measuring insert with form B-head
With Ø6 insertion tube - for use mainly in the low pressure range

Type HMI80 - Measuring insert with form B-head
With Ø8 insertion tube - for use mainly in the low pressure range

Type HMMI - Mineral-insulated measuring insert with B-head
For use up to 600°C - mainly in the low pressure range

Type HR - reduced tip for fast response time
For Measurement of temperatures

Type HTMS - multi-spot thermometer
For measurement in multiple spots in high temperature areas

Type MCB - Marine Connection Box
Enclosure for sensors and transmitters

Type MI60 - Measuring insert for form A-B-D
With Ø6 insertion tube - for form A-B-D and also for mounting in B-head

Type MI80 - Measuring insert For form A
With Ø8 insertion tube - for form B and also for mounting in B-head

Type MMI - Mineral-insulated measuring insert
Designed for form A-B-C-D-E-F-G and also for mounting in B-head

Type MNS - Mineral-insulated tank thermometer
Used for measurement in insulation and concrete surroundings

Type NLI - Multi-spot sensor - Measurement of volume
Used for measuring of average temperatures in tank systems

Type NL Cryogenic - multi-spot sensor
For cryogenic use - measurement in multiple spots -170°C to +95°C

Type NS - Tank thermometer - Roll-up sensor
For measurement of temperatures in pipelines and tank systems

Type OPE - with Ex-head
For use in refineries, chemical plants and harzardous installations

Type OPX - with Ex-head / reduced tip
Flanged mounted thermometer - fast response time

Type PMK - Mineral-insulated with cable
Fast response time, good resistance to vibrations and harsh environments.

Type PTE - Wire sensor - straight thermometer
For mouting in immerrsion wells, in gases and Machinery e.g. bearings

Type PTI - insertion thermometer - Classified
For measurement of temperatures in e.g. meat and fruit

Type PTR - Threaded thermometer - Classified
With fixed insert and without extension length

Type PTV - for mounting on walls
For Measurement of temperatures in rooms

Type PTVP - for wall mounting in cold rooms
For use in refrigerated holds, cargo and free compartments

Type PV - Wire sensor with angular bending
For measurement of temperatures in machinery

Type S - with angular connector
Classified - for use in gases, vapours and fluids.

Type SGN - Mini sensor
With reduced tip for fast response time

Type WLS - Water-Level-Sensor - multi-spot sensor
For continuous measurement of the water / oil interface